OSD don't continue after reboot(restart computer task sequence)

$
0
0

I create a restart computer task sequence(reboot into"currently installed default operating system") after install some softwares

but I found the OSD will stop after reboot. why it will stop? how to fix it?

the The following is log files.

smsts-20140530-095634

Successfully completed the action (Patch IE9_Patches_1405) with the exit win32 code 0	TSManager	2014/5/30 9:56:34	1808 (0x0710)
MP server http://PRI1.ABC.COM. Ports 80,443. CRL=false.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Setting authenticator	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set authenticator in transport	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Sending StatusMessage	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Setting message signatures.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Setting the authenticator.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
CLibSMSMessageWinHttpTransport::Send: URL: PRI1.ABC.COM:80  CCM_POST /ccm_system/request	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Request was successful.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSLastActionRetCode=0	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSLastActionSucceeded=true	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Clear local default environment	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Updated security on object C:\_SMSTaskSequence.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSNextInstructionPointer=44	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a TS execution environment variable _SMSTSNextInstructionPointer=44	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSInstructionStackString=17 20 26	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a TS execution environment variable _SMSTSInstructionStackString=17 20 26	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Save the current environment block	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Successfully save execution state and environment to local hard disk	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Start executing an instruction. Instruction name: Reboot. Instruction pointer: 44	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSCurrentActionName=Reboot	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSNextInstructionPointer=44	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a local default variable SMSRebootMessage	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a local default variable SMSRebootTimeout	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSLogPath=C:\WINDOWS\CCM\Logs\SMSTSLog	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Expand a string: smsboot.exe /target:HD	TSManager	2014/5/30 9:56:34	1808 (0x0710)

smsts

Expand a string: 	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Command line for extension .exe is "%1" %*	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set command line: smsboot.exe /target:HD	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Start executing the command line: smsboot.exe /target:HD	TSManager	2014/5/30 9:56:34	1808 (0x0710)
!--------------------------------------------------------------------------------------------!	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Expand a string: WinPEandFullOS	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Executing command line: smsboot.exe /target:HD	TSManager	2014/5/30 9:56:34	1808 (0x0710)
========================= [ smsboot.exe ] =========================	Reboot	2014/5/30 9:56:34	2572 (0x0A0C)
Command line: '"smsboot.exe" /target:HD'	Reboot	2014/5/30 9:56:34	2572 (0x0A0C)
SMSTSRebootDelay=3	Reboot	2014/5/30 9:56:34	2572 (0x0A0C)
SMSTSRebootMessage=正在安装新的 Microsoft Windows 操作系统。必须重新启动计算机才能继续。	Reboot	2014/5/30 9:56:34	2572 (0x0A0C)
SMSTSRebootRequested=HD	Reboot	2014/5/30 9:56:34	2572 (0x0A0C)
Process completed with exit code 0	TSManager	2014/5/30 9:56:34	1808 (0x0710)
!--------------------------------------------------------------------------------------------!	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Successfully completed the action (Reboot) with the exit win32 code 0	TSManager	2014/5/30 9:56:34	1808 (0x0710)
MP server http://PRI1.ABC.COM. Ports 80,443. CRL=false.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Setting authenticator	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set authenticator in transport	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Sending StatusMessage	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Setting message signatures.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Setting the authenticator.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
CLibSMSMessageWinHttpTransport::Send: URL: PRI1.ABC.COM:80  CCM_POST /ccm_system/request	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Request was successful.	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSLastActionRetCode=0	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Set a global environment variable _SMSTSLastActionSucceeded=true	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Clear local default environment	TSManager	2014/5/30 9:56:34	1808 (0x0710)
Updated security on object C:\_SMSTaskSequence.	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set a global environment variable _SMSTSNextInstructionPointer=45	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set a TS execution environment variable _SMSTSNextInstructionPointer=45	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set a global environment variable _SMSTSInstructionStackString=17 20 26	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set a TS execution environment variable _SMSTSInstructionStackString=17 20 26	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Save the current environment block	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Successfully save execution state and environment to local hard disk	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Reboot to local harddisk	TSManager	2014/5/30 9:56:35	1808 (0x0710)
_OSDGinaIsConfigured variable set to TRUE	TSManager	2014/5/30 9:56:35	1808 (0x0710)
_SMSTSServiceStartType variable set to 	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Command line for extension .exe is "%1" %*	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set command line: "bcdedit.exe"	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Executing command line: "bcdedit.exe"	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Process completed with exit code 0	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Calling RebootSystem()	TSManager	2014/5/30 9:56:35	1808 (0x0710)
OSD type of task sequence. ignore the service window setting	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Updated security on object C:\_SMSTSVolumeID.7159644d-f741-45d5-ab29-0ad8aa4771ca.	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Path variable OSDrive converted from C: to CE0B39280000100000000000:	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Updated security on object C:\_SMSTaskSequence.	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set a global environment variable _SMSTSNextInstructionPointer=45	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set a TS execution environment variable _SMSTSNextInstructionPointer=45	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set a global environment variable _SMSTSInstructionStackString=17 20 26	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Set a TS execution environment variable _SMSTSInstructionStackString=17 20 26	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Save the current environment block	TSManager	2014/5/30 9:56:35	1808 (0x0710)
Expand a string: %_SMSTSMDataPath%\Logs	TSManager	2014/5/30 9:56:35	1808 (0x0710)
==============================[ OSDSetupHook.exe ]==============================	OSDSetupHook	2014/5/30 9:57:59	908 (0x038C)
Executing task sequence	OSDSetupHook	2014/5/30 9:57:59	908 (0x038C)
Loading the Task Sequencing Environment from "C:\_SMSTaskSequence\TSEnv.dat".	OSDSetupHook	2014/5/30 9:57:59	908 (0x038C)
Environment scope successfully created: Global\{51A016B6-F0DE-4752-B97C-54E6F386A912}	OSDSetupHook	2014/5/30 9:57:59	908 (0x038C)
Environment scope successfully created: Global\{BA3A3900-CA6D-4ac1-8C28-5073AFC22B03}	OSDSetupHook	2014/5/30 9:57:59	908 (0x038C)
Debug shell is enabled	OSDSetupHook	2014/5/30 9:58:00	908 (0x038C)
Successfully enabled debug command shell support.	OSDSetupHook	2014/5/30 9:58:00	908 (0x038C)
Configuring local administrator account	OSDSetupHook	2014/5/30 9:58:00	908 (0x038C)
Re-assign all drive letters...	OSDSetupHook	2014/5/30 9:58:00	908 (0x038C)
The drive information which has no drive letter can not be found. No need to re-assign driver letters.	OSDSetupHook	2014/5/30 9:58:00	908 (0x038C)
Installing SMS client	OSDSetupHook	2014/5/30 9:58:00	908 (0x038C)
Client already installed.	OSDSetupHook	2014/5/30 9:58:00	908 (0x038C)
Moving logs to SMS client directory	OSDSetupHook	2014/5/30 9:58:00	908 (0x038C)